A Study of Single Photon Emission Computed Tomography by using Geant4/GATE
DOI:
https://doi.org/10.48165/Keywords:
SPECT, Quality Control, Quadrant Bar Phantom, Monte Carlo, GATEAbstract
The aim of this research is to validate and investigate the Geant4/GATE platform for the simulation of a dual-head detector SIEMENS Symbia E gamma camera installed in El-Kaser El-Ainy (Nuclear Medicine and Radiotherapy Unit) at Cairo University. Each camera consists of a lead collimator, scintillation crystal, and head shielding. The back compartment consists of photomultiplier tubes and electronic circuits behind the crystal. The photoelectric effect, Compton scattering, atomic ionization, bremsstrahlung, multiple scattering, and Rayleigh scattering are included in the simulated physics processes. The experimental data from the Quality Control measurements (Energy resolution, Uniformity, Spatial resolution and Sensitivity) versus the simulation results from GATE are compared.All The measurements are performed by using the radioisotope Tc-99m to determine the energy resolution and extrinsic sensitivity with a Low Energy High Resolution (LEHR) collimator and to ensure the quality of the scintillation crystal without collimator by measuring the uniformity. Other collimators are also used to estimate their extrinsic spatial resolutions and the corresponding extrinsic sensitivity values. In addition, a quadrant bar phantom consisting of 4 sets of lead bars in each quadrant is used to determine the Modulation Transfer Function (MTF) as a characteristic of the camera intrinsic spatial resolution.
References
Abdalrhman, N. E., Maria, R. F., Mario, D., et al. (2017). Quality control in dual head γ-cameras: Comparison between methods and software used for image analysis. ISSSD Proceedings, Santo Domingo, Dominican Republic.
Agostinelli, S., Allison, J., Amako, K., et al. (2003). GEANT4—A simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A, 506, 250–303.
Assié, K., Breton, V., Buvat, I., et al. (2004). Monte Carlo simulation in PET and SPECT instrumentation using GATE. Nuclear Instruments and Methods in Physics Research Section A, 527, 180–189.
Buvat, I., & Castiglioni, I. (2002). Monte Carlo simulations in SPET and PET. Quarterly Journal of Nuclear Medicine, 46, 48–61.
International Atomic Energy Agency (IAEA). (2009). Quality assurance for SPECT systems (IAEA Human Health Series No. 6). IAEA, Vienna.
International Atomic Energy Agency (IAEA). (2017). IAEA-NMQC toolkit for Fiji application: Version 1.00 user’s manual. IAEA, Vienna.
Jan, S., Santin, G., Strul, D., et al. (2004). GATE: A simulation toolkit for PET and SPECT. Physics in Medicine and Biology, 49, 4543–4561.
Momennezhad, M., Sadeghi, R., & Nasseri, S. (2012). Development of GATE Monte Carlo simulation for a dual-head gamma camera. Radiation Physics and Technology, 5(2), 222–228.
Park, M. J., Park, K. S., Leek, J.-S., & Kim, Y.-K. (2009). Validation of a GATE model for the simulation of a Trionix TRIAD SPECT camera. Journal of the Korean Physical Society, 55(2), 681–687.
SIEMENS. (2014). SIEMENS Symbia E and S system specifications (MI-1263).
Taherparvar, P., & Sadremomtaz, A. (2018). Development of GATE Monte Carlo simulation for a CsI pixelated gamma camera dedicated to high-resolution animal SPECT. Australasian Physical & Engineering Sciences in Medicine, 41(1), 31–39.
Zaidi, H. (1999). Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Medical Physics, 26, 574–608.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.