Use of Polyaxial Locking Plate and Rod Reconstruction in the Treatment of Tibial Diaphyseal Fractures in Dogs
DOI:
https://doi.org/10.48165/ijvsbt.2026.22.06.29Keywords:
Dog, Plate-rod fixation, Polyaxial locking plate, Tibial diaphyseal fractureAbstract
Clinical efficacy of the polyaxial locking plate (PAX) combined with intramedullary (IM) pinning - the plate-rod technique - was assessed in six dogs aged 6-28 months, irrespective of breed and sex, with mid-diaphyseal tibial fractures. Males predominated (83.33%), and road traffic accidents were the leading cause (83.33%) among these cases. Closed oblique fractures accounted for 66.66% of cases, the remainder being spiral. Surgery was performed at a mean of 4.83 ±0.83 days post-injury under a standardized anaesthetic protocol. A cranio-medial approach was used, and the PAX system’s ability to angle screws up to 15° from perpendicular appeared to provide stable fixation across fracture configurations. Fixation used 2.7 mm or 3.5 mm PAX plates combined with 1.8-3.0 mm IM pins. Radiographs on days 0, 15, 30, 60 and 90 tracked alignment, implant position, and healing. One case (23 kg, high activity level) showed transient implant bending. Lameness improved progressively, reaching grade I (normal weight-bearing) by day 60 in all six dogs, and radiographic union was achieved in all cases by day 90. The polyaxial plate’s limited-contact design supported early weight-bearing and reduced postoperative complications.
Downloads
References
Ali, B. (2013). Incidence, occurrence, classification and outcome of small animal fractures: A retrospective study (2005–2010). World Academy of Science, Engineering and Technology, 7, 3–27.
Arthurs, G. (2015). Advances in internal fixation locking plates. In Practice, 37(1), 13–20.
Barnhart, M. D., Rides, C. F., Kennedy, S. C., Aiken, S. W., Walls, C. M., Horstman, C. L., Mason, D., Chandler, J. C., Brourman, J. D., Murphy, S. M., & Pike, F. (2013). Fracture repair using a polyaxial locking plate system (PAX). Veterinary Surgery, 42(1), 60–66.
Bednarski, R., Grimm, K., Harvey, R., Lukasik, V. M., Penn, W. S., Sargent, B., & Spelts, K. (2011). AAHA anesthesia guidelines for dogs and cats. Journal of the American Animal Hospital Association, 47(6), 377–385.
Cook, J. L., Tomlinson, J. L., & Reed, A. L. (1999). Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: A prospective clinical study. Veterinary Surgery, 28(5), 315–321.
El-Shafey, S., El-Mezyen, A. E., Behery, A., & Abd El-Raouf, M. (2022). Tibial and fibular fractures in dogs and cats: A retrospective study. Zagazig Veterinary Journal, 50(1), 52–61.
Harasen, G. (2003). Common long bone fractures in small animal practice—Part 2. Canadian Veterinary Journal, 44, 503–504.
Johnson, A. L., Houlton, J. E., & Vannini, R. (2005). AO principles of fracture management in the dog and cat. AO Publishing.
Kostenko, E., Šengaut, J., & Maknickas, A. (2024). Machine learning in assessing canine bone fracture risk: A retrospective and predictive approach. Applied Sciences, 14(11), 4867.
Li, B., Yang, Y., & Jiang, L. S. (2015). Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: A systematic review. European Journal of Orthopaedic Surgery and Traumatology, 25(1), 53–63.
Nadkarni, B., Srivastav, S., Mittal, V., & Agarwal, S. (2008). Use of locking compression plates for long bone non-unions without removing existing intramedullary nail. Journal of Trauma and Acute Care Surgery, 65(2), 482–486.
Piermattei, D. L., & Flo, G. L. (2006). Fractures: Classification, diagnosis and treatment. In T. W. Fossum (Ed.), Handbook of small animal orthopaedics and fracture repair (4th ed., pp. 25–139). Saunders Elsevier.
Piermattei, D. L., & Johnson, K. A. (2006). An atlas of surgical approaches to the bones and joints of the dog and cat (4th ed.). Saunders Elsevier.
Radha, M. S., Nagaraja, B. N., Murthy, K. S., Girish, M. H., & Anilkumar, M. C. (2023). Incidence of tibial fractures in dogs. Indian Journal of Veterinary Surgery, 44(1), 1–4.
Raghunath, M., Singh, M., Yadav, R. K., & Singh, S. S. (2007). Distribution and classification of canine long bone fractures. Indian Veterinary Journal, 84, 1243–1246.
Reddy, J. M. K., Dilipkumar, D., Chandrasekhar, E. L., Kulkarni, S., Vijaykumar, M., & Dhoolappa, M. (2021). Evaluation of hematobiological parameters in repair of femoral fractures using titanium implants in dogs. Journal of Experimental Zoology, India, 24(1), 223–226.
Robinson, D. A. (2014). Orthopedic follow-up evaluations: Identifying complications. Today’s Veterinary Practice, 5, 9–10.
Rüedi, T. P., & Murphy, W. M. (2000). AO principles of fracture management. Thieme.
Seaman, R. L., & Simpson, A. M. (2004). Fractures of the humerus. Clinical Techniques in Small Animal Practice, 19, 120–127.
Surbhi. (2011). Biomechanical and clinical evaluation of acrylic and epoxy-pin external skeletal fixation systems in dogs [Doctoral dissertation, Indian Veterinary Research Institute, Izatnagar, Bareilly, Uttar Pradesh, India].
Vallem, K., Reddy, J. M. K., Sravanthi, M., & Kumar, R. S. (2025). Use of polyaxial locking plate and rod reconstruction in femur fractures in dogs. Indian Journal of Veterinary Sciences and Biotechnology, 21(1), 25–29.
Vasseur, P. B., Johnson, A. L., Budsberg, S. C., Lincoln, J. D., Toombs, J. P., Whitehair, J. G., & Lentz, E. L. (1995). Efficacy of carprofen in the treatment of osteoarthritis in dogs. Journal of the American Veterinary Medical Association, 206(6), 807–811.
Wilkens, K. J., Curtiss, S., & Lee, M. A. (2008). Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison. Journal of Orthopaedic Trauma, 22(9), 624–628.
Published
Issue
Section
License
Copyright (c) 2026 Indian Journal of Veterinary Sciences and Biotechnology

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.